DT-6X60 Embedded Network Processor Platform User's Manual RELEASE.VERSION 2.0 379 Campus Drive, Suite 100 Somerset, NJ 08873 fax: 732 667-
DT-6X60 User's Manual - Platform (Build 2.0) 2 PHYSICAL D ESCRIPTION Figure 2: DT-6X60 Front View 2.1 POWER INTERFACES 2.1.1 48 V DC POWER
DT-6X60 User's Manual - Platform (Build 2.0) The serial console port interface, which is labeled as CON on the DT-6XXX, requires a standard RJ45
DT-6X60 User's Manual - Platform (Build 2.0) 3 INSTALLATION This chapter contains the steps needed to install and cable the DT-6X60. A #2 Philli
DT-6X60 User's Manual - Platform (Build 2.0) 3) Attach the LAN data transport cable 4) Attach console cable by plugging one end of an RJ45-ter
DT-6X60 User's Manual - Platform (Build 2.0) 06/07/07 Datatek Applications Inc. 14 6. Rack-Mount: The Environmental Operating Range of 5
DT-6X60 User's Manual - Platform (Build 2.0) 4 CABLING 4.1 SERIAL CONSOLE CONNECTION AND CONFIGURATION 4.1.1 CABLING THE DT-6X60 SERIAL CONSOLE
DT-6X60 User's Manual - Platform (Build 2.0) Important! A modular cable with “SPECIAL WIRING” can be ordered using the table above or built us
DT-6X60 User's Manual - Platform (Build 2.0) 5 QUICK-START C ONFIGURATION G UIDE There are two levels of configuring a DT-6X60: platform and app
DT-6X60 User's Manual - Platform (Build 2.0) <DT-6X60> install ↵ application or package name ? NAME=tn3270 ↵ name of ftp download server
DT-6X60 User's Manual - Platform (Build 2.0) 6 DT-6X60 COMMAND R EFERENCE All DT-6XXX software is composed of two components. One component, cal
DT-6X60 User's Manual - Platform (Build 1.0) TABLE OF CONTENTS TABLE OF CONTENTS...
DT-6X60 User's Manual - Platform (Build 2.0) Backspace erases one character and @ deletes the current line of input. The del key kills most co
DT-6X60 User's Manual - Platform (Build 2.0) Table 5: Command Reference table 06/07/07 Datatek Applications Inc. 21 Section NumberCategory
DT-6X60 User's Manual - Platform (Build 2.0) 6.3 SYSTEM PLATFORM CONFIGURATION – NON IP NETWORK COMMANDS 6.3.1 SYSTEM CONSOLE USER HELP - HELP S
DT-6X60 User's Manual - Platform (Build 2.0) (enter). The user is again prompted for a line number. When finished, the user types a newline in r
DT-6X60 User's Manual - Platform (Build 2.0) 6.3.7 CHANGE PASSWORD - CHGPASS Syntax: chgpass OLD=<old> NEW=<new> CONFIRM=<new>
DT-6X60 User's Manual - Platform (Build 2.0) 6.4 SYSTEM PLATFORM CONFIGURATION – IP NETWORK RELATED COMMANDS 6.4.1 CLOSED USER GROUPS - CUG Synt
DT-6X60 User's Manual - Platform (Build 2.0) The IP address and subnet mask are used to determine whether a destination IP address is on the sam
DT-6X60 User's Manual - Platform (Build 2.0) After the hostname is input or changed, the DT-6X60 must be rebooted in order for the name to becom
DT-6X60 User's Manual - Platform (Build 2.0) duplex, while 'auto' allows auto-configuration. The 'phy' configuration is inde
DT-6X60 User's Manual - Platform (Build 2.0) 6.5 SOFTWARE ADMINISTRATION COMMANDS 6.5.1 INSTALLING A PLATFORM UPGRADE - INSTALL Syntax: See sect
DT-6X60 User's Manual - Platform (Build 2.0) 6.3.4 System Label Configuration - label...
DT-6X60 User's Manual - Platform (Build 2.0) If parameters are omitted from the command line, install will prompt for them. When prompted for th
DT-6X60 User's Manual - Platform (Build 2.0) Each application instance is allowed to have its own user changeable password for configuration pur
DT-6X60 User's Manual - Platform (Build 2.0) The back and retr commands remember the previous SRV, LOC, and FILE values and provide them next ti
DT-6X60 User's Manual - Platform (Build 2.0) To delete all values for a keyword, type the word “none” as the value. Special characters and escap
DT-6X60 User's Manual - Platform (Build 2.0) 6.8 RUN-TIME COMMANDS 6.8.1 DISPLAY CONNECTIONS – DC OR DCONN Syntax: dc | dconn [app [app#]][ -f
DT-6X60 User's Manual - Platform (Build 2.0) reports only connections that are associated with instances, and shows the instance ownership of ea
DT-6X60 User's Manual - Platform (Build 2.0) The cpu subcommand reports CPU utilization by process. Processes may be associated with instance n
DT-6X60 User's Manual - Platform (Build 2.0) sclk: 0 0% 113992 eth0: 132 0% 8912 SW+0: 127 0% 4682 SW+1: 0 0
DT-6X60 User's Manual - Platform (Build 2.0) 6.8.3.6 TRACE ROUTE - DIAG TRACERT OR DIAG TRTE Syntax: diag tracert <IP Address> diag trte
DT-6X60 User's Manual - Platform (Build 2.0) router is supposed to send back an ICMP Time Exceeded message to the source system. Tracert determi
DT-6X60 User's Manual - Platform (Build 2.0) 6.9.4 Standby Logs – stby dlog, stby reset ...
DT-6X60 User's Manual - Platform (Build 2.0) The <instance> parameter is an optional argument to specify the beginning instance number to
DT-6X60 User's Manual - Platform (Build 2.0) 6.9 HIGH AVAILABILITY OPTION The High Availability option couples two DT-6X60 modules as an active
DT-6X60 User's Manual - Platform (Build 2.0) minute interval allows the console operator time to investigate what the problem is and take correc
DT-6X60 User's Manual - Platform (Build 2.0) 6.9.2.2 OPERATIONAL CONFIGURATION – STBYUPD CFG The assignment of application types to instances, i
DT-6X60 User's Manual - Platform (Build 2.0) propagating to the standby. If the active survives AGE minutes of operations with the new configura
DT-6X60 User's Manual - Platform (Build 2.0) The help command at the standby console shows only the commands that ARE allowed. The date command
DT-6X60 User's Manual - Platform (Build 2.0) 7 APPENDIX A: CONSOLE C ABLE- SPECIAL W IRING D IAGRAMS Figure 5: Console Cable Pin Assigment
DT-6X60 User's Manual - Platform (Build 2.0) 7.1 THE DB9 CONSOLE ADAPTER Some Personal Computers use a 9-pin DB9 interface for serial communica
DT-6X60 User's Manual - Platform (Build 2.0) 8 APPENDIX B: SNMP MIB VARIABLE DATABASE AND TRAPS The DT-6XXX SNMP V1 agent supports a multitude o
DT-6X60 User's Manual - Platform (Build 2.0) 06/07/07 Datatek Applications Inc. 49 MIB Variable Number Name MIB Console Equivalent Acces
DT-6X60 User's Manual - Platform (Build 2.0) 14.7 Special Provisions...
DT-6X60 User's Manual - Platform (Build 2.0) MIB Variable Number Name MIB Console Equivalent Access Notes 1.3.6.1.2.1.6.9.0 TcpCurrEstab
DT-6X60 User's Manual - Platform (Build 2.0) 9 APPENDIX C: TCP/UDP PORT NUMBERS The DT-6X60 uses the following TCP and UDP ports. These ports ca
DT-6X60 User's Manual - Platform (Build 2.0) 10 APPENDIX D: THE DISPLAY MEASUREMENTS (DM) REPORT The DT-6X60 platform maintains measurements o
DT-6X60 User's Manual - Platform (Build 2.0) IP 15 0 datagrams that can't be fragmented Measurement descriptions: IP 1: The total number o
DT-6X60 User's Manual - Platform (Build 2.0) 10.2 TCP – DM TCP <DT-6X60> dm tcp tcp: TCP 1 1215000 packets sent 74247 data packets (
DT-6X60 User's Manual - Platform (Build 2.0) TCP 13 0 persist timeouts TCP 14 0 connections dropped by persist timeout TCP 15 10223 keepalive
DT-6X60 User's Manual - Platform (Build 2.0) 10.3 UDP – DM UDP <DT-6X60> dm udp udp: 834716 datagrams received UDP 1 0 with incom
DT-6X60 User's Manual - Platform (Build 2.0) 10.4 ICMP – DM ICMP Note - within the output and input histograms embedded in this report, only pa
DT-6X60 User's Manual - Platform (Build 2.0) Measurement descriptions: ICMP 1: The number of ICMP messages that the entity received but determin
DT-6X60 User's Manual - Platform (Build 2.0) 10.5 ETH – DM ETH <tuna: DT-6160> dm eth Name Mtu Network Address Ipkts I
DT-6X60 User's Manual - Platform (Build 2.0) IMPORTANT SAFETY INSTRUCTIONS The exclamation point within an equilateral triangle is intended to a
DT-6X60 User's Manual - Platform (Build 2.0) 11 APPENDIX E: BRIEF DESCRIPTIONS OF DT-6XXX APPLICATIONS 11.1 IP-BHI The IP-BHI (BiSync Host Inte
DT-6X60 User's Manual - Platform (Build 2.0) LoopCare® product. The LoopCare product is the evolution of the Lucent Technologies MLT operations
DT-6X60 User's Manual - Platform (Build 2.0) 11.9 IP-SPOOL Many existing networking equipment consoles have the need for a dedicated print devi
DT-6X60 User's Manual - Platform (Build 2.0) The MultiMate application was designed to eliminate the wasteful expense of external PADs and port-
DT-6X60 User's Manual - Platform (Build 2.0) 12 APPENDIX F: DT-6X60 SPECIFICATIONS To maintain compliance with the above-mentioned EMC standard
DT-6X60 User's Manual - Platform (Build 2.0) 12.6 POWER REQUIREMENTS Voltages Current Draw Power Input Requirements DT-6X60 Operating Voltage
DT-6X60 User's Manual - Platform (Build 2.0) 13 HARDWARE WARRANTY The warranty period for hardware shall be ninety (90) days from the date of sh
DT-6X60 User's Manual - Platform (Build 2.0) 14.3 SOFTWARE SUPPORT SOFTWARE support is not provided by Manufacturer, or its affiliates or subsid
DT-6X60 User's Manual - Platform (Build 2.0) DFARS 252.227-7013 or subparagraphs (c)(1) and (2) of the Commercial HARDWARE Software-Restricted R
DT-6X60 User's Manual - Platform (Build 2.0) 1 INTRODUCTION Two products are covered in this User Manual: the DT-6160 and the DT-6260 Embedded N
DT-6X60 User's Manual - Platform (Build 2.0) 1.1 MULTIPLE APPLICATION SUPPORT The DT-6X60 can support one or more different types of application
DT-6X60 User's Manual - Platform (Build 2.0) Application Name Description X25PAD Eliminates the need, complexity, and expense of specialize
Komentáře k této Příručce